SMHF4215S

Produktinformationen "Crane Interpoint SMHF4215S DC/DC-Wandler 35-55V, 15V, 1A Space"
Radiation tolerant space DC-DC converter
  • -Single event effects (SEE) LET performance to 86 MeV cm2/mg
  • -Total ionizing dose (TID) guaranteed per MIL-STD-883 method 1019, radiation hardness assurance (RHA) L = 50 krad(Si), R = 100 krad(Si)
  • -50 - 300 rad(Si)/sec dose rate (Condition A)
  • -10 mrad(Si)/sec dose rate (Condition D) 
€¢ Operating temperature -55°C to +125°C 
€¢ Screened to MIL-PRF-38534 Class H and K
€¢ Input voltage range 35 to 55 volts
€¢ Transient protection 80 volts for 50 ms
€¢ Fully isolated
€¢ Fixed high frequency switching
€¢ Inhibit function
€¢ Synchronization input
€¢ Indefinite short circuit protection
€¢ Undervoltage lockout
Eingangsspannung VDC nom.: 42
Ausgangsspannung VDC: 15
Ausgangsstrom (A): 1,4 - 10
Leistungsklasse: Low Power 10-99W
Gehäuse: Metallgehäuse
Kühlmethode: Konvektion
Zielmarkt: Luft- & Raumfahrt
TBD
TBD

Verwandte Artikel

SMHF42-Serie

Crane Interpoint SMHF4205D DC/DC-Wandler 35-55V, +/-5V, 1,68A Space Dualausgang
Radiation tolerant space DC-DC converter -Single event effects (SEE) LET performance to 86 MeV cm2/mg -Total ionizing dose (TID) guaranteed per MIL-STD-883 method 1019, radiation hardness assurance (RHA) L = 50 krad(Si), R = 100 krad(Si) -50 - 300 rad(Si)/sec dose rate (Condition A) -10 mrad(Si)/sec dose rate (Condition D) €¢ Operating temperature -55°C to +125°C €¢ Screened to MIL-PRF-38534 Class H and K €¢ Input voltage range 35 to 55 volts €¢ Transient protection 80 volts for 50 ms €¢ Fully isolated €¢ Fixed high frequency switching €¢ Inhibit function €¢ Synchronization input €¢ Indefinite short circuit protection €¢ Undervoltage lockout
zzgl. 19% MwSt.
Crane Interpoint SMHF4205S DC/DC-Wandler 35-55V, 5V, 2,4A Space
Radiation tolerant space DC-DC converter -Single event effects (SEE) LET performance to 86 MeV cm2/mg -Total ionizing dose (TID) guaranteed per MIL-STD-883 method 1019, radiation hardness assurance (RHA) L = 50 krad(Si), R = 100 krad(Si) -50 - 300 rad(Si)/sec dose rate (Condition A) -10 mrad(Si)/sec dose rate (Condition D) €¢ Operating temperature -55°C to +125°C €¢ Screened to MIL-PRF-38534 Class H and K €¢ Input voltage range 35 to 55 volts €¢ Transient protection 80 volts for 50 ms €¢ Fully isolated €¢ Fixed high frequency switching €¢ Inhibit function €¢ Synchronization input €¢ Indefinite short circuit protection €¢ Undervoltage lockout
zzgl. 19% MwSt.
Crane Interpoint SMHF4212D DC/DC-Wandler 35-55V, +/-12V, 0,875A Space Dualausgang
Radiation tolerant space DC-DC converter -Single event effects (SEE) LET performance to 86 MeV cm2/mg -Total ionizing dose (TID) guaranteed per MIL-STD-883 method 1019, radiation hardness assurance (RHA) L = 50 krad(Si), R = 100 krad(Si) -50 - 300 rad(Si)/sec dose rate (Condition A) -10 mrad(Si)/sec dose rate (Condition D) €¢ Operating temperature -55°C to +125°C €¢ Screened to MIL-PRF-38534 Class H and K €¢ Input voltage range 35 to 55 volts €¢ Transient protection 80 volts for 50 ms €¢ Fully isolated €¢ Fixed high frequency switching €¢ Inhibit function €¢ Synchronization input €¢ Indefinite short circuit protection €¢ Undervoltage lockout
zzgl. 19% MwSt.
Crane Interpoint SMHF4212S DC/DC-Wandler 35-55V, 12V, 1,25A Space
Radiation tolerant space DC-DC converter -Single event effects (SEE) LET performance to 86 MeV cm2/mg -Total ionizing dose (TID) guaranteed per MIL-STD-883 method 1019, radiation hardness assurance (RHA) L = 50 krad(Si), R = 100 krad(Si) -50 - 300 rad(Si)/sec dose rate (Condition A) -10 mrad(Si)/sec dose rate (Condition D) €¢ Operating temperature -55°C to +125°C €¢ Screened to MIL-PRF-38534 Class H and K €¢ Input voltage range 35 to 55 volts €¢ Transient protection 80 volts for 50 ms €¢ Fully isolated €¢ Fixed high frequency switching €¢ Inhibit function €¢ Synchronization input €¢ Indefinite short circuit protection €¢ Undervoltage lockout
zzgl. 19% MwSt.
Crane Interpoint SMHF4215D DC/DC-Wandler 35-55V, +/-15V, 0,7A Space Dualausgang
Radiation tolerant space DC-DC converter -Single event effects (SEE) LET performance to 86 MeV cm2/mg -Total ionizing dose (TID) guaranteed per MIL-STD-883 method 1019, radiation hardness assurance (RHA) L = 50 krad(Si), R = 100 krad(Si) -50 - 300 rad(Si)/sec dose rate (Condition A) -10 mrad(Si)/sec dose rate (Condition D) €¢ Operating temperature -55°C to +125°C €¢ Screened to MIL-PRF-38534 Class H and K €¢ Input voltage range 35 to 55 volts €¢ Transient protection 80 volts for 50 ms €¢ Fully isolated €¢ Fixed high frequency switching €¢ Inhibit function €¢ Synchronization input €¢ Indefinite short circuit protection €¢ Undervoltage lockout
zzgl. 19% MwSt.
Crane Interpoint SMHF4215S DC/DC-Wandler 35-55V, 15V, 1A Space
Radiation tolerant space DC-DC converter -Single event effects (SEE) LET performance to 86 MeV cm2/mg -Total ionizing dose (TID) guaranteed per MIL-STD-883 method 1019, radiation hardness assurance (RHA) L = 50 krad(Si), R = 100 krad(Si) -50 - 300 rad(Si)/sec dose rate (Condition A) -10 mrad(Si)/sec dose rate (Condition D) €¢ Operating temperature -55°C to +125°C €¢ Screened to MIL-PRF-38534 Class H and K €¢ Input voltage range 35 to 55 volts €¢ Transient protection 80 volts for 50 ms €¢ Fully isolated €¢ Fixed high frequency switching €¢ Inhibit function €¢ Synchronization input €¢ Indefinite short circuit protection €¢ Undervoltage lockout
zzgl. 19% MwSt.
Crane Interpoint SMHF423R3S DC/DC-Wandler 35-55V, 3,3V, 2,4A Space
Radiation tolerant space DC-DC converter -Single event effects (SEE) LET performance to 86 MeV cm2/mg -Total ionizing dose (TID) guaranteed per MIL-STD-883 method 1019, radiation hardness assurance (RHA) L = 50 krad(Si), R = 100 krad(Si) -50 - 300 rad(Si)/sec dose rate (Condition A) -10 mrad(Si)/sec dose rate (Condition D) €¢ Operating temperature -55°C to +125°C €¢ Screened to MIL-PRF-38534 Class H and K €¢ Input voltage range 35 to 55 volts €¢ Transient protection 80 volts for 50 ms €¢ Fully isolated €¢ Fixed high frequency switching €¢ Inhibit function €¢ Synchronization input €¢ Indefinite short circuit protection €¢ Undervoltage lockout
zzgl. 19% MwSt.
Crane Interpoint SMHF425R2S DC/DC-Wandler 35-55V, 5,2V, 2,4A Space
Radiation tolerant space DC-DC converter -Single event effects (SEE) LET performance to 86 MeV cm2/mg -Total ionizing dose (TID) guaranteed per MIL-STD-883 method 1019, radiation hardness assurance (RHA) L = 50 krad(Si), R = 100 krad(Si) -50 - 300 rad(Si)/sec dose rate (Condition A) -10 mrad(Si)/sec dose rate (Condition D) €¢ Operating temperature -55°C to +125°C €¢ Screened to MIL-PRF-38534 Class H and K €¢ Input voltage range 35 to 55 volts €¢ Transient protection 80 volts for 50 ms €¢ Fully isolated €¢ Fixed high frequency switching €¢ Inhibit function €¢ Synchronization input €¢ Indefinite short circuit protection €¢ Undervoltage lockout
zzgl. 19% MwSt.
Newsletter Anmeldung Symbolbild

Newsletter

Abonnieren Sie jetzt kostenlos unseren E-Mail-Newsletter